Skip to main content

Table 8 Mean log10-reduction (± standard deviations) of virus titer under CO2-shielding gas via hard cavitation at a frequency of 27 kHz (n = 5)

From: Novel method for reduction of virus load in blood plasma by sonication

Time

60 min

120 min

180 min

240 min

300 min

Mean log-reduction of virus titer in PBS (log10TCID50/ml)

 BVDV

1.7 (± 0.1)

3.8 (± 0.2)

≥ 3.8 (± 0.2)

≥ 3.8 (± 0.2)

≥ 3.8 (± 0.2)

 SFV

0.7 (± 0.1)

2.7 (± 0.1)

4.2 (± 0.3)

5.0 (± 0.3)

≥ 5.7 (± 0.3)

 PRV

1.0 (± 0.1)

3.0 (± 0.2)

4.7 (± 0.3)

4.5 (± 0.3)

≥ 5.5 (± 0.4)

 PPV

0 (± 0)

0 (± 0)

0 (± 0)

0 (± 0)

0 (± 0)

Mean log-reduction of virus titer in plasma (log10TCID50/ml)

 BVDV

0.5 (± 0.1)

1.6 (± 0.1)

1.3 (± 0.1)

2.4 (± 0.2)

2.5 (± 0.2)

 SFV

0 (± 0)

0 (± 0.1)

1.1 (± 0.1)

2.9 (± 0.2)

4.6 (± 0.3)

 PRV

0.6 (± 0.1)

1.6 (± 0.1)

1.9 (± 0.1)

2.8 (± 0.2)

3.4 (± 0.3)

 PPV

0 (± 0)

0 (± 0)

0 (± 0)

0 (± 0)

0 (± 0)