Table 2 Multivariate logistic regression models for pre- and post-procedural prediction of PPMI

From: A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement

 

OR (95% CI)

p value

Pre-procedural prediction model

 Prior RBBB

9.36 (3.09, 29.23)

< 0.001**

 Pre-procedural AVA, per 0.1 cm2

1.17 (1.00, 1.37)

0.042*

Post-procedural prediction model

 Prior RBBB

10.46 (3.40, 33.29)

< 0.001***

 Pre-procedural AVA, per 0.1 cm2

1.41 (1.12, 1.79)

0.004**

 AVA ratio

1.72 (1.00, 2.91)

0.043*

 AVA–PNA ratio

0.01 (0.00, 0.92)

0.052

  1. The multivariate regression models were obtained via forward and backward variable selection for the pre- and post-procedural prediction models (see “Methods”)
  2. AVA ratio, ratio of post-procedural aortic valve area to pre-procedural area; AVA–PNA ratio, ratio of post-procedural aortic valve area to prosthetic nominal area; CI, confidence interval; OR, odds ratio; other abbreviations as in Table 1