Lung flooding enables efficient lung sonography and tumour imaging in human ex vivo and porcine in vivo lung cancer model
European Journal of Medical Research volume 18, Article number: 23 (2013)
Abstract
Background
Sonography has become the imaging technique of choice for guiding intraoperative interventions in abdominal surgery. Due to artefacts from residual air content, however, videothoracoscopic and open intraoperative ultrasound-guided thermoablation of lung malignancies are impossible. Lung flooding is a new method that allows complete ultrasound imaging of lungs and their tumours.
Methods
Fourteen resected tumourous human lung lobes were examined transpleurally with B-mode ultrasound before (in atelectasis) and after lung flooding with isotonic saline solution. In two swine, the left lung was filled with 15 ml/kg isotonic saline solution through the left side of a double-lumen tube. Lung tumours were simulated by transthoracic ultrasound-guided injection of 5 ml of purified bovine serum albumin in glutaraldehyde, centrally into the left lower lung lobe. The rate of tumour detection, the severity of disability caused by residual gas, and sonomorphology of the lungs and tumours were assessed.
Results
The ex vivo tumour detection rate was 100% in flooded human lung lobes and 43% (6/14) in atelectatic lungs. In all cases of atelectasis, sonographic tumour imaging was impaired by residual gas. Tumours and atelectatic tissue were isoechoic. In 28% of flooded lungs, a little residual gas was observed that did not impair sonographic tumour imaging. In contrast to tumours, flooded lung tissue was hyperechoic, homogeneous, and of fine-grained structure. Because of the bronchial wall three-laminar structure, sonographic differentiation of vessels and bronchi was possible. In all cases, malignant tumours in the flooded lung appeared well-demarcated from the lung parenchyma. Adenocarcinoma, squamous, and large cell carcinomas were hypoechoic. Bronchioloalveolar cell carcinoma was slightly hyperechoic. Transpleural sonography identifies endobronchial tumour growth and bronchial wall destruction. With transthoracic sonography, the flooded animal lung can be completely examined in vivo. There is no residual gas, which interferes with ultrasound. Pulmonary vessels and bronchi are clearly differentiated. Simulated lung lesions can easily be detected inside the lung lobe.
Conclusions
Lung flooding enables complete lung sonography and tumour detection. We have developed a novel method that efficiently uses ultrasound for guiding intraoperative interventions in open and endoscopic lung surgery.
Background
In cases of inoperable primary or metastatic liver tumours, radiofrequency or microwave ablation are accepted therapeutic options [1–3]. As a less invasive therapy, ablation can be performed under percutaneous, laparoscopic, or open intraoperative ultrasound guidance [4–7]. Lung tumours in the parenchyma are undetectable by ultrasound due to artefacts caused by residual air content. Because of this, transthoracic, videothoracoscopic, or open intraoperative ultrasound-guided interstitial thermotherapy for treating non-resectable primary and secondary lung tumours is impossible. Lung flooding could be a new method to image the lung and tumours completely with ultrasound. This study aimed to investigate lung sonography and tumour imaging under flooding conditions, ex vivo on resected human lung lobes and in vivo in a porcine model.
Methods
Ex vivo examinations of resected human lung lobes
Human lung samples
Between April 2011 and March 2012, 14 patients with lung tumours were enrolled. This study was approved by the ethics committee of the Medical Association of Thuringia. All patients received a lung lobectomy. In 13 cases, presurgical histological diagnosis of a malignant tumour was confirmed using a percutaneous or transbronchial needle biopsy (10 bronchial carcinomas, one lung metastasis of a colon carcinoma, one peribrochial lymph node metastasis of a thyroid carcinoma, and one peribrochial lymph node metastasis of a renal cell carcinoma). Due to a central hamatochondroma, one case also required middle lobe resection. The average age of the patients was 67.5 years (range 54 to 85 years), from whom the right lower lobe (n = 6), right upper lobe (n = 4), left lower lobe (n = 2), or the middle lobe (n = 2) were resected. The greatest tumour diameter, determined by computed tomography scan, was 3.2 cm (range 1.6 to 8.0 cm).
Intraoperative procedures
Lungs were ventilated with 100% oxygen after intubation with a double-lumen endotracheal tube. After anterolateral thoracotomy in the lateral decubitus position, the segmental pulmonary arteries and lobar vein were dissected, parenchymal fusions between the lobes were cut with staplers, and the lobar vein and secondary segmental pulmonary arteries were divided. A mediastinal lymphadenectomy was carried out before dividing the lobar bronchus to achieve complete atelectasis of the lung lobe.
Lung flooding
The resected lobe was prepared for flooding immediately ex vivo, and mucus in the segmental and subsegmental bronchi was removed. An expanded polytetrafluoroethylene graft was anastomosed end-to-end to the lobar bronchus and used as a conduit for fluid instillation. After venting the conduit, an infusion system was connected. Filling was performed passively using the gravity of the liquid flowing from an infusion bottle suspended 50 cm above heart level. Filling continued until functional residual capacity of the lobe was achieved (Figure 1).
Sonographic examination
Before and after liquid filling, the lung lobe was examined transpleurally by ultrasound (MikroMaxx™ Portable Ultrasound System; SonoSite, Inc., Bothell, WA, USA) in a liquid bath of 30°C isotonic NaCl solution with a linear probe (L 38e, 10 to 5 MHz; SonoSite) and an intraoperative probe (SLA, 13 to 6 MHz; SonoSite) in fundamental B-mode. The surgeon was not the ultrasound examiner. The investigator did not know the preoperative computed tomographic findings. We assessed tumour detection rate, the imaging disability caused by residual gas, and the sonomorphology of the lung and the tumour, and their spatial relationships to the bronchi and pulmonary vessels.
Histopathological examinations of the resection margins were performed immediately after the ultrasound. For the definitive histopathological examination, the specimen was fixed in formaldehyde after a cut through the lobe.
In vivo ultrasound detection of simulated tumours in a porcine model
Animals
Animal experiments were carried out on two female pigs (Deutsches Landschwein breed; weight range: 33 to 38 kg, average: 35.5 kg), with permission from the Veterinary Department of the Thuringian State Authority for Food Protection and Fair Trading, and in compliance with the National Animal Protection Act.
Anaesthesia and artifical respiration
Anaesthesia was induced by intramuscular injection of 10 mg/kg-1 ketamine. Additionally, 6.25 mg droperidol and 10 mg diazepam were administered after cannulation of an ear vein, and the animals were orotracheally intubated during spontaneous breathing (Magill tube, inner diameter = 8.5 mm, Mallinckrodt™, Covidien, Neustadt, Germany). After relaxation with pancuronium bromide (0.2 mg/kg-1) and deepening of the anaesthesia by fentanyl (10 μg/kg-1), artificial respiration was started with 1.0 to 1.5 minimum alveolar concentration (MAC) of isoflurane in an oxygen/nitrous oxide mix (fraction of inspired oxygen, FIO2 = 0.3). After tracheotomy, a left-sided Robertshaw double-lumen tube with an extra-long bronchial lane (size 39 Ch; special product by Mallinckrodt Medical, Dublin, Ireland) was inserted. The correct position of the tube was checked by fibre bronchoscopy (BF 3C30 Fiber Bronchoscope; Olympus, Tokyo, Japan). Anaesthesia was changed to total intravenous anaesthesia with propofol (10 mg/kg/h), fentanyl (0.05 to 0.08 μg/kg–1/min–1), and pancuronium bromide (2.5 μg/kg–1/min–1), and the FIO2 was raised to 1.0.
Mechanical ventilation was performed with an ICU respirator (Servo 900, Siemens AG, Munich, Germany), using a volume-controlled setting (tidal volume 10 ml/kg-1; respiratory rate 16 to 20 min-1; positive end-expiratory pressure = 6 cm H2O). The end-expiratory carbon dioxide partial pressure (pCO2) was maintained between 35 and 45 mmHg. We infused 4 to 6 ml/kg/h Ringer’s lactate and 2 to 4 ml/kg/h hydroxyethyl starch (HES 10%) as base infusions. Body temperature was maintained between 36 and 38°C by warming the infusion solution and covering the animals with an isolation sheet.
The electrocardiogram, arterial blood pressure, capillary oxygen saturation, and expiratory CO2 concentration were measured and recorded continuously (Datex AS/3 Compact Multiparameter Patient Monitor; Datex-Ohmeda Corp., Helsinki, Finland). Arterial blood gas samples were analysed every 30 minutes (ABL System 625; Radiometer Medical, Copenhagen, Denmark).
Lung flooding
Thirty minutes after ventilation with FIO2 = 1.0, the left endobronchial leg was disconnected from the respirator. The infusion system was immediately connected to the left tube leg and the lung was slowly filled with 15 ml/kg (accordingly the functional residual capacity of a lung wing) of an isotonic saline solution, preheated to body temperature. A single filling was performed passively using the gravity of the liquid flowing from an infusion bottle suspended 50 cm above heart level. The liquid was left in the lung for 30 minutes. During unilateral lung ventilation, the respirator settings remained unchanged.
Thirty minutes after flooding and completion of the sonographic examinations, the liquid was drained passively through the opened left tube leg after placing the animals in the Trendelenburg position (posterior of animal elevated 30°), followed by simultaneous ventilation of both lungs. After 30 minutes of two-lung ventilation, the animal was killed by injection of a lethal dose of sodium pentobarbital and potassium chloride.
Tumour simulation
After lung flooding, a 17-G needle was placed centrally in the left lower lung lobe, using percutaneous transpleural ultrasound guidance. Five millilitres of a fluid composed of purified bovine serum albumin and glutaraldehyde (Bioglue™; CryoLife Europa, Guildford, UK) was injected to simulate a lung tumour.
Lung sonography
After liquid filling and tumour simulation, the left lung was examined transthoracically and transpleurally with ultrasound (MikroMaxx System; SonoSite, Inc.) with a linear (L 38e, 10 to 5 MHz) and curved probe (C11e, 8 to 5 MHz), in fundamental B-mode (Figure 2). We assessed the detection of simulated lesions and the sonomorphology of the lung.
Results
Ex vivo examination of resected human lung lobes
Sonomorphology of the lungs and tumours
The tumour detection rate and sonomorphology are detailed in Table 1. Sonographic examination of the atelectatic lung was greatly limited by residual gas, whereby tumours were only detectable in 43% (6/14) of the cases. The detected tumours could be clearly demarcated from the surrounding lung tissue in only 15% of the cases. Tumours and atelectatic tissue presented as isoechoic, making distinction difficult (Figure 3).
After flooding, 71.4% (10/14) of the lung lobes could be completely examined by ultrasound, and small amounts of residual gas were observed in 28.6% (4/14) of the cases. Normal lung parenchyma was homogeneous and rich in echogenicity, with a fine-grained structure. Vessels and bronchi differentiated themselves as structures free of echo within the parenchyma, and the bronchial wall displayed its three-layered structure. All tumours were clearly visualised by ultrasound after flooding. Except for bronchioloalveolar carcinoma, all of the other types of non-small cell lung carcinoma were predominantly hypoechoic in comparison to surrounding lung tissue. The tumours were irregularly configured with finger-shaped extensions, and were well-demarcated from the surrounding lung tissue. The typical sonographic images of the main non-small cell lung carcinoma types are as follows: squamous cell carcinoma appears as a predominantly inhomogeneous texture with hypoechoic necrotic areas and a hypoechoic ‘halo’ (Figure 4); adenocarcinoma appears as predominantly homogeneous hypoechoic texture (Figure 5); and large cell carcinoma with neuroendocrine differentiation appears homogeneously hypoechoic with a trabecular or nest-like growth. By contrast, bronchioloalveolar cell carcinoma shows a slightly hyperechoic image. The tumour appears homogenous with respect to the bronchi and vessels, without evidence of infiltration into these structures, and is difficult to differentiate from healthy lung tissue (Figure 6).
When diagnosing bronchus wall infiltration, ultrasound is superior to computed tomography. Transpleural sonography can clearly identify endobronchial tumour growth and destruction of the bronchial wall (Figures 3 and 7).
In vivo ultrasound examination of simulated lung tumours in an animal model
With transthoracic sonography, the flooded animal lung can be completely examined. There is no residual gas to interfere with ultrasound imaging. Pulmonary vessels and bronchi are clearly differentiated. Mediastinal organs such as the heart and thoracic aorta are visible behind the lung. Simulated lung lesions can be detected within the lung lobe. Tumours simulated by Bioglue™ (CryoLife Europa) were completely echo-free with a well-defined margin (Figure 8).
Immediately after reventilation of both lungs, sonographic examination shows many air inclusions (Figure 9). After 10 minutes the sound waves were reflected completely by the air-filled lung, and image quality deteriorated considerably.
Both animals survived the procedure without haemodynamic complications. Recovery of the flooding liquid was 35% of the instilled volume in both animals.
Discussion
Intraoperative sonography is a valuable tool in the surgery of parenchymatous organs. The exact visualisation of the location, size, and spreading of a tumour has a decisive influence on operating strategy [8, 9]. In the last five years, sonography has become the imaging technique of choice for guiding intraoperative interventional procedures such as ablation techniques for primary and secondary liver malignancies. Ultrasound gives real-time feedback of the tumour and applicator location, allowing accurate and consistent placement of ablative instruments, as well as evaluation of the developing lesion.
Sonographic imaging of the lung is impossible due to sound reflection due to air content. In comparison with laparoscopic ultrasound-guided tumour detection or interstitial thermotherapy of liver tumours, videothoracoscopic applications of ultrasound are limited. Only in cases of actual tumour infiltration into the pleura, or of bronchial obstruction by the tumour with pneumonic infiltration of the lung tissue up to the pleura, is partial tumour imaging by ultrasound possible [10, 11].
We developed a new method for effective ultrasound imaging of the lung. After lung flooding with physiologic saline solution, the lung tissue and lung tumours can be completely visualised, and distinguished, by ultrasound. Tumours are detectable centrally in the lung lobe and differentiate themselves from the surrounding lung parenchyma. Infiltration of the tumour into adjoining functional structures is also identifiable. Furthermore, the surrounding healthy lung parenchyma appears homogeneous and rich in echogenicity, with a fine-grained structure. This is due to multiple scattering at the alveolar septum and water interface. Adenocarcinomas, squamous cell carcinomas, and large cell carcinomas are predominantly hypoechoic in comparison to lung tissue. Bronchioloalveolar cell carcinoma shows a slightly hyperechoic image. The special tumour cell spread inside the alveolar space may result in a higher acoustic impedance.
Tumour detection and complete visualisation by ultrasound is currently inadequate in the atelectatic lung because residual gas in the non-collapsed bronchi strongly hinders complete sonographic imaging. Furthermore, overall organ volume decreases by approximately 80% in the atelectatic lung compared with the ventilated organ. As a result, the true distance between observed tumours and functional lung structures cannot be accurately determined. Our results also show that atelectatic lung tissue and malignant tumour tissue have almost identical echogenicities (that is, isoechoic), and because of this, precise sonographic discrimination between the tumour and healthy lung tissue is not possible.
In animal experiments, a complete one-lung flooding of the non-collapsed lung inside the closed thoracic cavity is possible. The volume of the flooded lung corresponds to the functional residual capacity. Prerequisites for this approach include using a double-lumen tube for safe side-separation, and filling the lung once passively using the gravity of the liquid flowing from an infusion bottle suspended 50 cm above heart level. To minimise the time required for complete sonographic examination, the animal should be placed so that the lung is in the dependent position. Lung flooding enables a complete transthoracic lung sonography. The three-layered bronchial wall structure and blood vessels are clearly differentiated by B-mode sonography. The colour-coded duplex sonography is not helpful because there is no perfusion in the flooded lung. The oscillatory flow occurs in both the vessels and bronchi. Simulated tumours deep inside the parenchyma are easily detected by sonography after lung flooding. Sonography under flooding clearly indicates the spatial relationship between lesions and functional structures.
After passively draining the fluid through the opened tube, complete reventilation of the flooded lung is possible within 30 minutes. The residual saline will be resorbed into the alveoli, assisted by positive-pressure ventilation. All animals survived the procedure. In earlier experiments, we showed that one-lung flooding causes no serious effects on haemodynamic or gas exchange. In comparison with purposeful atelectasis, which is the usual procedure in open and thoracoscopic surgery, lung flooding reduced the pulmonary right-left shunt. This increases the arterial oxygen partial pressure that would otherwise be caused by pulmonary blood flow inhibition [12]. In survival experiments after one-lung flooding, the early postoperative phase after extubation and spontaneous breathing showed a moderate increase in the intrapulmonary shunt fraction that was normalised within 8 hours [13]. A continuous infusion of pentoxifylline increases the partial arterial oxygen pressure and decreases the pulmonary shunt volume during reventilation after flooding, and in the early phase after extubation [14]. Subsequent studies have shown that 1 hour after one-lung flooding, extravascular water in the reventilated lung increases by 5%. After only 24 hours, both the flooded and non-flooded lung no longer differed in their wet-to-dry ratios. The maximum surfactant loss caused by flooding was 47% of the calculated surfactant pool of the respective lung [15]. Finally, histological and immunological investigations demonstrated that one-lung flooding is not associated with destruction of the alveolar texture, atelectasis-provoking surfactant loss, or any irreversible damage to the pulmonary parenchyma [16]. The results available so far in animal studies allow us to conclude that lung flooding over 60 minutes for the purpose of transthoracic or videothoracoscopic lung sonography is safe and justifiable.
The limitations of this new approach are as follows. Lung flooding, both for ultrasound-guided diagnosis and interventional procedures during videothoracoscopy, cannot be performed up to functional residual capacity because this would reduce the space required for satisfactory viewing and endothoracic surgical manipulation. Tumour obstruction of the main lobar bronchi can hinder the fluid filling and sonographic examination of the lung. Severe obstructive lung disease with pulmonary hypertension may be a contraindication for lung flooding.
Conclusions
Lung flooding enables complete lung sonography and tumour detection, which is otherwise impossible with ultrasound. We created a novel method to use ultrasound for guiding minimally invasive interventional procedures such as thermoablation of lung tumours during videothoracoscopy or open surgery. Lung flooding might be an important and easily accomplished prerequisite for efficiently using high-frequency focused ultrasound to treat lung tumours.
Abbreviations
- CT:
-
Computed tomography
- FIO2:
-
Fraction of inspired oxygen
- HES:
-
Hydroxyethyl starch
- LLL:
-
Left lower lobe
- LNM:
-
Lymph node metastasis
- MAC:
-
Minimum alveolar concentration
- ML:
-
Middle lobe
- pCO2:
-
Carbon dioxide partial pressure
- RLL:
-
Right lower lobe
- RUL:
-
Right upper lobe.
References
Lau WY, Leung TW, Yu SC, Ho SK: Percutaneous local ablative therapy for hepatocellular carcinoma: a review and look into the future. Ann Surg 2003, 237: 171–179.
Brace CL, Hinshaw JL, Lubner MG: Thermal ablation for the treatment of abdominal tumors. J Vis Ex 2011, 49: 2596.
Lubner MG, Brace CL, Hinshaw JL, Lee FT Jr: Microwave tumor ablation: mechanism of action, clinical results, and devices. J Vasc Interv Radiol 2010, 21: 192–203.
Siperstein A, Garland A, Engle K, Rogers S, Berber E, String A: Laparoscopic radiofrequency ablation of primary and metastatic liver tumors. Technical considerations. Surg Endosc 2000, 14: 400–405.
Santambrogio R, Bianchi P, Pasta A, Palmisano A, Montorsi M: Ultrasound-guided interventional procedures of the liver during laparoscopy: technical considerations. Surg Endosc 2002, 16: 349–354.
Lee SD, Han HS, Cho JY, Yoon YS, Hwang DW, Jung K, Yoon CJ, Kwon Y, Kim JH: Safety and efficacy of laparoscopic radiofrequency ablation for hepatic malignancies. J Korean Surg Soc 2012, 83: 36–42.
Machi J, Uchida S, Sumida K, Limm WM, Hundahl SA, Oishi AJ, Furumoto NL, Oish RH: Ultrasound-guided radiofrequency thermal ablation of liver tumors: percutaneous, laparoscopic, and open surgical approaches. J Gastrointest Surg 2001, 5: 477–489.
Zimmer T, Stolzel U, Bader M, Koppenhagen K, Hamm B, Buhr H, Riecken EO, Wiedenmann B: Endoscopic ultrasonography and somatostatin receptor scintigraphy in the preoperative localisation of insulinomas and gastrinomas. Gut 1996, 39: 562–568.
Lo CM, Lai EC, Liu CL, Fan ST, Wong J: Laparoscopy and laparoscopic ultrasonography avoid exploratory laparotomy in patients with hepatocellular carcinoma. Ann Surg 1998, 227: 527–532.
Prosch H, Mathis G, Mostbeck GH: Percutaneous ultrasound in diagnosis and staging of lung cancer. Ultraschall Med 2008, 29: 466–478.
Kroegel C, Reißig A: Transthorakale Sonographie. Grundlagen und Anwendung. Stuttgart New York: Georg ThiemeVerlag; 2000.
Klinzing S, Lesser T, Schubert H, Bloos F, Klein U, Bartel M: Hemodynamics and gas exchange during experimental one-lung fluid flooding in pigs. Res Exp Med (Berl) 1999, 199: 87–94.
Klinzing S, Lesser T, Schubert H, Bartel M, Klein U: One-lung flooding for video-assisted thoracoscopic surgery in animal experiments on pigs - oxygenation and intrapulmonary shunt. Res Exp Med (Berl) 2000, 199: 333–340.
Klinzing S, Lesser T, Schubert H, Bartel M, Klein U: May pentoxifylline improve lung function after one-lung flooding? Res Exp Med (Berl) 2001, 200: 69–76.
Klinzing S, Lesser T, Schubert H, Bartel M, Klein U: Wet-to-dry ratio of lung tissue and surfactant outwash after one-lung flooding. Res Exp Med (Berl) 2000, 200: 27–33.
Lesser T, Klinzing S, Schubert H, Kosmehl H: Consequences of one-lung flooding: a histological and immunological investigation. Eur J Med Res 2008, 13: 432–438.
Acknowledgements
The authors thank Mrs. Petra Dobermann of the Institute of Animal Experimentation, Friedrich-Schiller University of Jena, for her active help with the animal experiments.
Author information
Authors and Affiliations
Corresponding author
Additional information
Competing interests
The authors declare that they have no competing interests, neither financial nor non-financial.
Authors’ contributions
TGL collected the data and wrote the manuscript. HS and SB performed the anaesthesia. FW was responsible for simulation of lung lesions and ultrasound technique. HS and FW co-wrote the manuscript and discussed the results with TGL. All authors read and approved the manuscript.
Authors’ original submitted files for images
Below are the links to the authors’ original submitted files for images.
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Lesser, T.G., Schubert, H., Bischoff, S. et al. Lung flooding enables efficient lung sonography and tumour imaging in human ex vivo and porcine in vivo lung cancer model. Eur J Med Res 18, 23 (2013). https://doi.org/10.1186/2047-783X-18-23
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/2047-783X-18-23